Residential or Commercial | Residential | ![]() | ![]() |
Installation Location | Indoor Only | ![]() | ![]() |
Exhaust Type | Single Vent | ![]() | ![]() |
Max Flow Rate | 6.6 GPM | ![]() | ![]() |
Flow Rate @ 50°F Rise | 4.4 GPM | ![]() | ![]() |
Flow Rate @ 80°F Rise | 2.8 GPM | ![]() | ![]() |
Temperature Range | 115°F - 140°F | ![]() | ![]() |
Production Status | Active | ![]() | ![]() |
Condensing | Yes | ![]() | ![]() |
Minimum Activation Flow Rate | 0.5 | ![]() | ![]() |
Water Quality | Treatment May Be Necessary | ![]() | ![]() |
Freeze Protection | Yes | ![]() | ![]() |
Freeze Protection Rating - Indoor Temp | 32°F | ![]() | ![]() |
Freeze Protection Rating - Outdoor Temp | N/A | ![]() | ![]() |
Recirculation Compatible? | Yes | ![]() | ![]() |
New Generation Model Number | N/A | ![]() | ![]() |
Previous Name | N/A | ![]() | ![]() |
Available Temperature Settings (with remote) | 115, 120, 125, 130, 135, 140°F | ![]() | ![]() |
Default Temperature Setting (without remote) | 120°F | ![]() | ![]() |
Default Temperature Program Setting Options (without remote) | 120, 130, 135, 140°F | ![]() | ![]() |
Production Date Range | 8/2014 - Present | ![]() | ![]() |
Min Gas Input (Btu) | 15000 | ![]() | ![]() |
Max Gas Input (Btu) | 120000 | ![]() | ![]() |
Height (in) | 27.2 | ![]() | ![]() |
Width (in) | 18.3 | ![]() | ![]() |
Depth (in) | 9.4 | ![]() | ![]() |
Weight (lbs) | 50 | ![]() | ![]() |
Thermal Efficiency | N/A | ![]() | ![]() |
Energy Factor | UEF=0.87 | ![]() | ![]() |
Afue | N/A | ![]() | ![]() |
Quick-Connect Compatible? | No | ![]() | ![]() |
Cold Water Connection Size (in) | 3/4 | ![]() | ![]() |
Hot Water Connection Size (in) | 3/4 | ![]() | ![]() |
Gas Connection Size (in) | 1/2 | ![]() | ![]() |
Power Supply | 120 VAC (60 Hz) | ![]() | ![]() |
Current Draw (A) | 1.77 | ![]() | ![]() |
Exhaust Vent Diameter Requirements | Centrotherm 2"-Flex | ![]() | ![]() |
Exhaust Vent Material Requirements | Centrotherm 2"-Flex only (Not applicable PVC venting) | ![]() | ![]() |
Max Vent Length with 1 elbow | 35’ with 45°-2elbow | ![]() | ![]() |
Vent Termination Clearances to Any Building Opening (ft) | Below = 4’, Side = 4’, or Above = 1’ | ![]() | ![]() |
Gas Supply Pressure Range | 4 - 10.5" WC | ![]() | ![]() |
Min Gas Line Size | 1/2" is N/A, 3/4" up to 30’ | ![]() | ![]() |
Water Pressure Rating (psi) | 15-150 | ![]() | ![]() |
Case Clearances (in) | Top = 12", Front = 4", Sides = 3", Back = 0" | ![]() | ![]() |
Combustion Air Requirements - using Indoor Air | 180 in² | ![]() | ![]() |
Combustion Air Requirements - using Outdoor Air | 100 in² | ![]() | ![]() |
Head Loss at 2 gpm | ![]() | ![]() | |
Cold Connection Height | 2.4" | ![]() | ![]() |
Power Consumption w/out Freeze Prevention | 83 Watts | ![]() | ![]() |
Power Consumption w/Freeze Prevention | 129 Watts | ![]() | ![]() |
Flow Meter Alarm | Yes, with optional remote | ![]() | ![]() |
Service Reminder | No | ![]() | ![]() |
Condensate Handling Method? | NC-1 | ![]() | ![]() |
Noise Rating (dB) | 48 dB | ![]() | ![]() |
Tested to UL Computer Controlled Safety Standards | Yes | ![]() | ![]() |
Flame Sensor | Yes | ![]() | ![]() |
High Limit Switch | Yes | ![]() | ![]() |
Lightning Protection | Yes | ![]() | ![]() |
Overheat Cutoff Fuse | Yes | ![]() | ![]() |
Temperature Lockout | Yes | ![]() | ![]() |
Ignition Type | Direct Electronic | ![]() | ![]() |
Case Material | Durable Steel Casing with Polyester Coating | ![]() | ![]() |
Color/Finish | Beige | ![]() | ![]() |
Flue Collar Material | Stainless Steel | ![]() | ![]() |
Primary Heat Exchanger Material | Copper | ![]() | ![]() |
Secondary Heat Exchanger Material | Stainless Steel | ![]() | ![]() |
Mounting Type | Wall Hung | ![]() | ![]() |
Package Contents | Anchoring Screws, Owner’s Guide, Warranty, Installation Manual | ![]() | ![]() |
Water Holding Capacity | 0.2 gallons | ![]() | ![]() |
Keypad/Thermostat Display | Not included | ![]() | ![]() |
Compatible Remote Controller Part # | RC-7651M | ![]() | ![]() |
Isolator Valve Part # | IK-WV-200-1-xx | ![]() | ![]() |
Freeze Protection | Yes | ![]() | ![]() |
Freeze Protection Kit Accessory | N/A | ![]() | ![]() |
Outdoor Vent Cap Part # | N/A | ![]() | ![]() |
Pipe Cover Part # | N/A | ![]() | ![]() |
Recess Box Part # | N/A | ![]() | ![]() |
High Elevation Adjustment | Yes (Max. 3,500 ft.) | ![]() | ![]() |
Quick-Connect Cord Part # | N/A | ![]() | ![]() |
System Controller Compatible? | No | ![]() | ![]() |
System Controller Part # | N/A | ![]() | ![]() |
Remote Controller Cord | Not Included | ![]() | ![]() |
Compatible Remote Controller Cord Part # | N/A | ![]() | ![]() |
Power Cord | Included attached | ![]() | ![]() |
![]() | ![]() |
ENERGY STAR® Qualified | Yes | ![]() | ![]() |
CSA | Yes [US Only] | ![]() | ![]() |
Mobile Home | No | ![]() | ![]() |
NSF | Yes | ![]() | ![]() |
SCAQMD (20 ppm) | Yes | ![]() | ![]() |
SCAQMD (55 ppm) | No | ![]() | ![]() |
UPC | Yes | ![]() | ![]() |
Energy Guide - Est. Yearly Energy Use | 127 therms | ![]() | ![]() |
Energy Guide - Est. Yearly Operating Cost | $138 | ![]() | ![]() |
UPC Low Lead | Yes | ![]() | ![]() |
ASME (HLW) | No | ![]() | ![]() |
ASME (H) | No | ![]() | ![]() |
ASME (NB) | No | ![]() | ![]() |
![]() | ![]() |
Heat Exchanger Warranty (w/out Recirculation) | 12 Years | ![]() | ![]() |
Heat Exchanger Warranty (w/Recirculation) | 3 Years w/Aquastat | ![]() | ![]() |
Parts Warranty | 5 Years | ![]() | ![]() |
Labor Warranty | 1 Year | ![]() | ![]() |
Residential or Commercial | Residential | ![]() | ![]() |
Installation Location | Indoor Only | ![]() | ![]() |
Exhaust Type | Single Vent | ![]() | ![]() |
Max Flow Rate | 6.6 GPM | ![]() | ![]() |
Flow Rate @ 50°F Rise | 4.4 GPM | ![]() | ![]() |
Flow Rate @ 80°F Rise | 2.8 GPM | ![]() | ![]() |
Temperature Range | 115°F - 140°F | ![]() | ![]() |
Production Status | Active | ![]() | ![]() |
Condensing | Yes | ![]() | ![]() |
Minimum Activation Flow Rate | 0.5 | ![]() | ![]() |
Water Quality | Treatment May Be Necessary | ![]() | ![]() |
Freeze Protection | Yes | ![]() | ![]() |
Freeze Protection Rating - Indoor Temp | 32°F | ![]() | ![]() |
Freeze Protection Rating - Outdoor Temp | N/A | ![]() | ![]() |
Recirculation Compatible? | Yes | ![]() | ![]() |
New Generation Model Number | N/A | ![]() | ![]() |
Previous Name | N/A | ![]() | ![]() |
Available Temperature Settings (with remote) | 115, 120, 125, 130, 135, 140°F | ![]() | ![]() |
Default Temperature Setting (without remote) | 120°F | ![]() | ![]() |
Default Temperature Program Setting Options (without remote) | 120, 130, 135, 140°F | ![]() | ![]() |
Production Date Range | 8/2014 - Present | ![]() | ![]() |
Min Gas Input (Btu) | 15000 | ![]() | ![]() |
Max Gas Input (Btu) | 120000 | ![]() | ![]() |
Height (in) | 27.2 | ![]() | ![]() |
Width (in) | 18.3 | ![]() | ![]() |
Depth (in) | 9.4 | ![]() | ![]() |
Weight (lbs) | 50 | ![]() | ![]() |
Thermal Efficiency | N/A | ![]() | ![]() |
Energy Factor | UEF=0.87 | ![]() | ![]() |
Afue | N/A | ![]() | ![]() |
Quick-Connect Compatible? | No | ![]() | ![]() |
Cold Water Connection Size (in) | 3/4 | ![]() | ![]() |
Hot Water Connection Size (in) | 3/4 | ![]() | ![]() |
Gas Connection Size (in) | 1/2 | ![]() | ![]() |
Power Supply | 120 VAC (60 Hz) | ![]() | ![]() |
Current Draw (A) | 1.77 | ![]() | ![]() |
Exhaust Vent Diameter Requirements | Centrotherm 2"-Flex | ![]() | ![]() |
Exhaust Vent Material Requirements | Centrotherm 2"-Flex only (Not applicable PVC venting) | ![]() | ![]() |
Max Vent Length with 1 elbow | 35’ with 45°-2elbow | ![]() | ![]() |
Vent Termination Clearances to Any Building Opening (ft) | Below = 4’, Side = 4’, or Above = 1’ | ![]() | ![]() |
Gas Supply Pressure Range | 4 - 10.5" WC | ![]() | ![]() |
Min Gas Line Size | 1/2" is N/A, 3/4" up to 30’ | ![]() | ![]() |
Water Pressure Rating (psi) | 15-150 | ![]() | ![]() |
Case Clearances (in) | Top = 12", Front = 4", Sides = 3", Back = 0" | ![]() | ![]() |
Combustion Air Requirements - using Indoor Air | 180 in² | ![]() | ![]() |
Combustion Air Requirements - using Outdoor Air | 100 in² | ![]() | ![]() |
Head Loss at 2 gpm | ![]() | ![]() | |
Cold Connection Height | 2.4" | ![]() | ![]() |
Power Consumption w/out Freeze Prevention | 83 Watts | ![]() | ![]() |
Power Consumption w/Freeze Prevention | 129 Watts | ![]() | ![]() |
Flow Meter Alarm | Yes, with optional remote | ![]() | ![]() |
Service Reminder | No | ![]() | ![]() |
Condensate Handling Method? | NC-1 | ![]() | ![]() |
Noise Rating (dB) | 48 dB | ![]() | ![]() |
Tested to UL Computer Controlled Safety Standards | Yes | ![]() | ![]() |
Flame Sensor | Yes | ![]() | ![]() |
High Limit Switch | Yes | ![]() | ![]() |
Lightning Protection | Yes | ![]() | ![]() |
Overheat Cutoff Fuse | Yes | ![]() | ![]() |
Temperature Lockout | Yes | ![]() | ![]() |
Ignition Type | Direct Electronic | ![]() | ![]() |
Case Material | Durable Steel Casing with Polyester Coating | ![]() | ![]() |
Color/Finish | Beige | ![]() | ![]() |
Flue Collar Material | Stainless Steel | ![]() | ![]() |
Primary Heat Exchanger Material | Copper | ![]() | ![]() |
Secondary Heat Exchanger Material | Stainless Steel | ![]() | ![]() |
Mounting Type | Wall Hung | ![]() | ![]() |
Package Contents | Anchoring Screws, Owner’s Guide, Warranty, Installation Manual | ![]() | ![]() |
Water Holding Capacity | 0.2 gallons | ![]() | ![]() |
Keypad/Thermostat Display | Not included | ![]() | ![]() |
Compatible Remote Controller Part # | RC-7651M | ![]() | ![]() |
Isolator Valve Part # | IK-WV-200-1-xx | ![]() | ![]() |
Freeze Protection | Yes | ![]() | ![]() |
Freeze Protection Kit Accessory | N/A | ![]() | ![]() |
Outdoor Vent Cap Part # | N/A | ![]() | ![]() |
Pipe Cover Part # | N/A | ![]() | ![]() |
Recess Box Part # | N/A | ![]() | ![]() |
High Elevation Adjustment | Yes (Max. 3,500 ft.) | ![]() | ![]() |
Quick-Connect Cord Part # | N/A | ![]() | ![]() |
System Controller Compatible? | No | ![]() | ![]() |
System Controller Part # | N/A | ![]() | ![]() |
Remote Controller Cord | Not Included | ![]() | ![]() |
Compatible Remote Controller Cord Part # | N/A | ![]() | ![]() |
Power Cord | Included attached | ![]() | ![]() |
![]() | ![]() |
ENERGY STAR® Qualified | Yes | ![]() | ![]() |
CSA | Yes [US Only] | ![]() | ![]() |
Mobile Home | No | ![]() | ![]() |
NSF | Yes | ![]() | ![]() |
SCAQMD (20 ppm) | Yes | ![]() | ![]() |
SCAQMD (55 ppm) | No | ![]() | ![]() |
UPC | Yes | ![]() | ![]() |
Energy Guide - Est. Yearly Energy Use | 127 therms | ![]() | ![]() |
Energy Guide - Est. Yearly Operating Cost | $138 | ![]() | ![]() |
UPC Low Lead | Yes | ![]() | ![]() |
ASME (HLW) | No | ![]() | ![]() |
ASME (H) | No | ![]() | ![]() |
ASME (NB) | No | ![]() | ![]() |
![]() | ![]() |
Heat Exchanger Warranty (w/out Recirculation) | 12 Years | ![]() | ![]() |
Heat Exchanger Warranty (w/Recirculation) | 3 Years w/Aquastat | ![]() | ![]() |
Parts Warranty | 5 Years | ![]() | ![]() |
Labor Warranty | 1 Year | ![]() | ![]() |