Residential or Commercial | Residential | ||
Installation Location | Indoor Only | ||
Exhaust Type | 2-pipe Direct Vent (SV convertible) | ||
Max Flow Rate | 7.1 GPM | ||
Flow Rate @ 50°F Rise | 5.8 GPM | ||
Flow Rate @ 80°F Rise | 3.7 GPM | ||
Temperature Range | 115°F - 140°F | ||
Production Status | Active | ||
Condensing | Yes | ||
Minimum Activation Flow Rate | 0.5 | ||
Water Quality | Treatment May Be Necessary |
Freeze Protection | Yes | ||
Freeze Protection Rating - Indoor Temp | -30°F | ||
Freeze Protection Rating - Outdoor Temp | N/A | ||
Recirculation Compatible? | Yes | ||
New Generation Model Number | N/A | ||
Previous Name | NRC83-DV-LP | ||
Available Temperature Settings (with remote) | 115, 120, 125, 130, 135, 140°F | ||
Default Temperature Setting (without remote) | 120°F | ||
Default Temperature Program Setting Options (without remote) | 120, 130, 135, 140°F | ||
Production Date Range |
Min Gas Input (Btu) | 15000 | ||
Max Gas Input (Btu) | 157000 | ||
Height (in) | 23.6 | ||
Width (in) | 13.8 | ||
Depth (in) | 6.7 | ||
Weight (lbs) | 41.0 | ||
Thermal Efficiency | N/A | ||
Energy Factor | UEF=0.89 | ||
Afue | N/A | ||
Quick-Connect Compatible? | No | ||
Cold Water Connection Size (in) | 3/4 | ||
Hot Water Connection Size (in) | 3/4 | ||
Gas Connection Size (in) | 3/4 | ||
Power Supply | 120 VAC (60 Hz) | ||
Current Draw (A) | 1.75 | ||
Exhaust Vent Diameter Requirements | 3" | ||
Exhaust Vent Material Requirements | PVC or CPVC | ||
Max Vent Length with 1 elbow | 57’ | ||
Vent Termination Clearances to Any Building Opening (ft) | Below = 1’, Side = 1’, or Above = 1’ | ||
Gas Supply Pressure Range | 8-14" WC | ||
Min Gas Line Size | 3/4" up to 30’ | ||
Water Pressure Rating (psi) | 15-150 | ||
Case Clearances (in) | Top = 12", Front = 4", Sides = 3", Back = 0" | ||
Combustion Air Requirements - using Indoor Air | 180 in² (Only if SV conversion) |
Combustion Air Requirements - using Outdoor Air | 100 in²(Only if SV conversion) | ||
Head Loss at 2 gpm | |||
Cold Connection Height | 2.3" | ||
Power Consumption w/out Freeze Prevention | 72 Watts | ||
Power Consumption w/Freeze Prevention | 138 Watts | ||
Flow Meter Alarm | Yes, with optional remote | ||
Service Reminder | No | ||
Condensate Handling Method? | NC-1 | ||
Noise Rating (dB) | 51 dB | ||
Tested to UL Computer Controlled Safety Standards | Yes | ||
Flame Sensor | Yes | ||
High Limit Switch | Yes | ||
Lightning Protection | Yes | ||
Overheat Cutoff Fuse | Yes | ||
Temperature Lockout | Yes | ||
Ignition Type | Direct Electronic | ||
Case Material | Durable Steel Casing with Polyester Coating | ||
Color/Finish | Beige | ||
Flue Collar Material | PVC | ||
Primary Heat Exchanger Material | Copper | ||
Secondary Heat Exchanger Material | Stainless Steel | ||
Mounting Type | Wall Hung | ||
Package Contents | Anchoring Screws, Owner’s Guide, Warranty, Installation Manual Guide, Warranty, Installation Manual | ||
Water Holding Capacity | 0.2 gallons |
Keypad/Thermostat Display | Not included | ||
Compatible Remote Controller Part # | RC-7651M | ||
Isolator Valve Part # | IK-WV-200-1-xx | ||
Freeze Protection | Yes | ||
Freeze Protection Kit Accessory | N/A | ||
Outdoor Vent Cap Part # | N/A | ||
Pipe Cover Part # | PC-1S | ||
Recess Box Part # | N/A |
High Elevation Adjustment | Yes | ||
Quick-Connect Cord Part # | N/A | ||
System Controller Compatible? | No | ||
System Controller Part # | N/A | ||
Remote Controller Cord | Not included | ||
Compatible Remote Controller Cord Part # | N/A | ||
Power Cord | Included attached | ||
ENERGY STAR® Qualified | Yes | ||
CSA | Yes | ||
Mobile Home | Yes | ||
NSF | Yes | ||
SCAQMD (20 ppm) | Yes | ||
SCAQMD (55 ppm) | No | ||
UPC | Yes |
Energy Guide - Est. Yearly Energy Use | 208 gallons | ||
Energy Guide - Est. Yearly Operating Cost | $501 | ||
UPC Low Lead | Yes | ||
ASME (HLW) | No | ||
ASME (H) | No | ||
ASME (NB) | No | ||
Heat Exchanger Warranty (w/out Recirculation) | 12 Years | ||
Heat Exchanger Warranty (w/Recirculation) | 3 Years |
Parts Warranty | 5 Years | ||
Labor Warranty | 1 Year |
Residential or Commercial | Residential | ||
Installation Location | Indoor Only | ||
Exhaust Type | 2-pipe Direct Vent (SV convertible) | ||
Max Flow Rate | 7.1 GPM | ||
Flow Rate @ 50°F Rise | 5.8 GPM | ||
Flow Rate @ 80°F Rise | 3.7 GPM | ||
Temperature Range | 115°F - 140°F | ||
Production Status | Active | ||
Condensing | Yes | ||
Minimum Activation Flow Rate | 0.5 | ||
Water Quality | Treatment May Be Necessary |
Freeze Protection | Yes | ||
Freeze Protection Rating - Indoor Temp | -30°F | ||
Freeze Protection Rating - Outdoor Temp | N/A | ||
Recirculation Compatible? | Yes | ||
New Generation Model Number | N/A | ||
Previous Name | NRC83-DV-LP | ||
Available Temperature Settings (with remote) | 115, 120, 125, 130, 135, 140°F | ||
Default Temperature Setting (without remote) | 120°F | ||
Default Temperature Program Setting Options (without remote) | 120, 130, 135, 140°F | ||
Production Date Range |
Min Gas Input (Btu) | 15000 | ||
Max Gas Input (Btu) | 157000 | ||
Height (in) | 23.6 | ||
Width (in) | 13.8 | ||
Depth (in) | 6.7 | ||
Weight (lbs) | 41.0 | ||
Thermal Efficiency | N/A | ||
Energy Factor | UEF=0.89 | ||
Afue | N/A | ||
Quick-Connect Compatible? | No | ||
Cold Water Connection Size (in) | 3/4 | ||
Hot Water Connection Size (in) | 3/4 | ||
Gas Connection Size (in) | 3/4 | ||
Power Supply | 120 VAC (60 Hz) | ||
Current Draw (A) | 1.75 | ||
Exhaust Vent Diameter Requirements | 3" | ||
Exhaust Vent Material Requirements | PVC or CPVC | ||
Max Vent Length with 1 elbow | 57’ | ||
Vent Termination Clearances to Any Building Opening (ft) | Below = 1’, Side = 1’, or Above = 1’ | ||
Gas Supply Pressure Range | 8-14" WC | ||
Min Gas Line Size | 3/4" up to 30’ | ||
Water Pressure Rating (psi) | 15-150 | ||
Case Clearances (in) | Top = 12", Front = 4", Sides = 3", Back = 0" | ||
Combustion Air Requirements - using Indoor Air | 180 in² (Only if SV conversion) |
Combustion Air Requirements - using Outdoor Air | 100 in²(Only if SV conversion) | ||
Head Loss at 2 gpm | |||
Cold Connection Height | 2.3" | ||
Power Consumption w/out Freeze Prevention | 72 Watts | ||
Power Consumption w/Freeze Prevention | 138 Watts | ||
Flow Meter Alarm | Yes, with optional remote | ||
Service Reminder | No | ||
Condensate Handling Method? | NC-1 | ||
Noise Rating (dB) | 51 dB | ||
Tested to UL Computer Controlled Safety Standards | Yes | ||
Flame Sensor | Yes | ||
High Limit Switch | Yes | ||
Lightning Protection | Yes | ||
Overheat Cutoff Fuse | Yes | ||
Temperature Lockout | Yes | ||
Ignition Type | Direct Electronic | ||
Case Material | Durable Steel Casing with Polyester Coating | ||
Color/Finish | Beige | ||
Flue Collar Material | PVC | ||
Primary Heat Exchanger Material | Copper | ||
Secondary Heat Exchanger Material | Stainless Steel | ||
Mounting Type | Wall Hung | ||
Package Contents | Anchoring Screws, Owner’s Guide, Warranty, Installation Manual Guide, Warranty, Installation Manual | ||
Water Holding Capacity | 0.2 gallons |
Keypad/Thermostat Display | Not included | ||
Compatible Remote Controller Part # | RC-7651M | ||
Isolator Valve Part # | IK-WV-200-1-xx | ||
Freeze Protection | Yes | ||
Freeze Protection Kit Accessory | N/A | ||
Outdoor Vent Cap Part # | N/A | ||
Pipe Cover Part # | PC-1S | ||
Recess Box Part # | N/A |
High Elevation Adjustment | Yes | ||
Quick-Connect Cord Part # | N/A | ||
System Controller Compatible? | No | ||
System Controller Part # | N/A | ||
Remote Controller Cord | Not included | ||
Compatible Remote Controller Cord Part # | N/A | ||
Power Cord | Included attached | ||
ENERGY STAR® Qualified | Yes | ||
CSA | Yes | ||
Mobile Home | Yes | ||
NSF | Yes | ||
SCAQMD (20 ppm) | Yes | ||
SCAQMD (55 ppm) | No | ||
UPC | Yes |
Energy Guide - Est. Yearly Energy Use | 208 gallons | ||
Energy Guide - Est. Yearly Operating Cost | $501 | ||
UPC Low Lead | Yes | ||
ASME (HLW) | No | ||
ASME (H) | No | ||
ASME (NB) | No | ||
Heat Exchanger Warranty (w/out Recirculation) | 12 Years | ||
Heat Exchanger Warranty (w/Recirculation) | 3 Years |
Parts Warranty | 5 Years | ||
Labor Warranty | 1 Year |