| Residential or Commercial | Residential | ![]() | ![]() |
| Installation Location | Outdoor Only | ![]() | ![]() |
| Exhaust Type | Exhaust thru Front cover | ![]() | ![]() |
| Max Flow Rate | 4.7 GPM | ![]() | ![]() |
| Flow Rate @ 50°F Rise | 6.1 GPM | ![]() | ![]() |
| Flow Rate @ 80°F Rise | 3.8 GPM | ![]() | ![]() |
| Temperature Range | 115°F - 140°F | ![]() | ![]() |
| Production Status | Active | ![]() | ![]() |
| Condensing | No | ![]() | ![]() |
| Minimum Activation Flow Rate | 0.5 | ![]() | ![]() |
| Water Quality | Treatment May Be Necessary | ![]() | ![]() |
| Freeze Protection | Yes | ![]() | ![]() |
| Freeze Protection Rating - Indoor Temp | N/A | ![]() | ![]() |
| Freeze Protection Rating - Outdoor Temp | -4°F | ![]() | ![]() |
| Recirculation Compatible? | Yes | ![]() | ![]() |
| New Generation Model Number | N/A | ![]() | ![]() |
| Previous Name | ![]() | ![]() | |
| Available Temperature Settings (with remote) | 115, 120, 125, 130, 135, 140°F | ![]() | ![]() |
| Default Temperature Setting (without remote) | 120°F | ![]() | ![]() |
| Default Temperature Program Setting Options (without remote) | 120, 125, 130, 140°F | ![]() | ![]() |
| Production Date Range | 12/2017 - Present | ![]() | ![]() |
| Min Gas Input (Btu) | 18000 | ![]() | ![]() |
| Max Gas Input (Btu) | 180000 | ![]() | ![]() |
| Height (in) | 23.6 | ![]() | ![]() |
| Width (in) | 13.8 | ![]() | ![]() |
| Depth (in) | 9.4 | ![]() | ![]() |
| Weight (lbs) | 49 | ![]() | ![]() |
| Thermal Efficiency | N/A | ![]() | ![]() |
| Energy Factor | UEF 0.82 | ![]() | ![]() |
| Afue | N/A | ![]() | ![]() |
| Quick-Connect Compatible? | Yes | ![]() | ![]() |
| Cold Water Connection Size (in) | 3/4 | ![]() | ![]() |
| Hot Water Connection Size (in) | 3/4 | ![]() | ![]() |
| Gas Connection Size (in) | 3/4 | ![]() | ![]() |
| Power Supply | 120 VAC (60 Hz) | ![]() | ![]() |
| Current Draw (A) | 1.34 amps | ![]() | ![]() |
| Exhaust Vent Diameter Requirements | N/A | ![]() | ![]() |
| Exhaust Vent Material Requirements | N/A | ![]() | ![]() |
| Max Vent Length with 1 elbow | N/A | ![]() | ![]() |
| Vent Termination Clearances to Any Building Opening (ft) | Below = 4’, Side = 4’, or Above = 1’ | ![]() | ![]() |
| Gas Supply Pressure Range | 8 - 14" WC | ![]() | ![]() |
| Min Gas Line Size | 1/2" up to 20 feet, 3/4" up to 125 feet. | ![]() | ![]() |
| Water Pressure Rating (psi) | 15-150 | ![]() | ![]() |
| Case Clearances (in) | Top = 12", Front = 4", Sides = 2", Back = 0" | ![]() | ![]() |
| Combustion Air Requirements - using Indoor Air | N/A | ![]() | ![]() |
| Combustion Air Requirements - using Outdoor Air | N/A | ![]() | ![]() |
| Head Loss at 2 gpm | 7 ft of head | ![]() | ![]() |
| Cold Connection Height | 1.9" | ![]() | ![]() |
| Power Consumption w/out Freeze Prevention | 69 Watts | ![]() | ![]() |
| Power Consumption w/Freeze Prevention | 161 Watts | ![]() | ![]() |
| Flow Meter Alarm | Yes | ![]() | ![]() |
| Service Reminder | Yes | ![]() | ![]() |
| Condensate Handling Method? | N/A | ![]() | ![]() |
| Noise Rating (dB) | Less than 60 dB | ![]() | ![]() |
| Tested to UL Computer Controlled Safety Standards | Yes | ![]() | ![]() |
| Flame Sensor | Yes | ![]() | ![]() |
| High Limit Switch | Yes | ![]() | ![]() |
| Lightning Protection | Yes | ![]() | ![]() |
| Overheat Cutoff Fuse | Yes | ![]() | ![]() |
| Temperature Lockout | Yes | ![]() | ![]() |
| Ignition Type | Direct Electronic | ![]() | ![]() |
| Case Material | Durable Steel Casing with Polyester Coating | ![]() | ![]() |
| Color/Finish | Beige | ![]() | ![]() |
| Flue Collar Material | N/A | ![]() | ![]() |
| Primary Heat Exchanger Material | Copper | ![]() | ![]() |
| Secondary Heat Exchanger Material | N/A | ![]() | ![]() |
| Mounting Type | Wall Hung | ![]() | ![]() |
| Package Contents | Anchoring Screws, Owner’s Guide, Warranty, Installation Manual | ![]() | ![]() |
| Water Holding Capacity | 0.2 gallons | ![]() | ![]() |
| Keypad/Thermostat Display | Yes | ![]() | ![]() |
| Compatible Remote Controller Part # | RC-7651M (USA) | ![]() | ![]() |
| Isolator Valve Part # | IK-WV-200-1-xx | ![]() | ![]() |
| Freeze Protection | Built in | ![]() | ![]() |
| Freeze Protection Kit Accessory | N/A | ![]() | ![]() |
| Outdoor Vent Cap Part # | N/A | ![]() | ![]() |
| Pipe Cover Part # | PC-2S | ![]() | ![]() |
| Recess Box Part # | RB-700-1 | ![]() | ![]() |
| High Elevation Adjustment | Yes | ![]() | ![]() |
| Quick-Connect Cord Part # | QC-2 | ![]() | ![]() |
| System Controller Compatible? | No | ![]() | ![]() |
| System Controller Part # | N/A | ![]() | ![]() |
| Remote Controller Cord | Included | ![]() | ![]() |
| Compatible Remote Controller Cord Part # | N/A | ![]() | ![]() |
| Power Cord | Not included | ![]() | ![]() |
![]() | ![]() |
| Heat Exchanger Warranty (w/out Recirculation) | 12 Years | ![]() | ![]() |
| Heat Exchanger Warranty (w/Recirculation) | 12 Years w/Aquastat | ![]() | ![]() |
| Residential or Commercial | Residential | ![]() | ![]() |
| Installation Location | Outdoor Only | ![]() | ![]() |
| Exhaust Type | Exhaust thru Front cover | ![]() | ![]() |
| Max Flow Rate | 4.7 GPM | ![]() | ![]() |
| Flow Rate @ 50°F Rise | 6.1 GPM | ![]() | ![]() |
| Flow Rate @ 80°F Rise | 3.8 GPM | ![]() | ![]() |
| Temperature Range | 115°F - 140°F | ![]() | ![]() |
| Production Status | Active | ![]() | ![]() |
| Condensing | No | ![]() | ![]() |
| Minimum Activation Flow Rate | 0.5 | ![]() | ![]() |
| Water Quality | Treatment May Be Necessary | ![]() | ![]() |
| Freeze Protection | Yes | ![]() | ![]() |
| Freeze Protection Rating - Indoor Temp | N/A | ![]() | ![]() |
| Freeze Protection Rating - Outdoor Temp | -4°F | ![]() | ![]() |
| Recirculation Compatible? | Yes | ![]() | ![]() |
| New Generation Model Number | N/A | ![]() | ![]() |
| Previous Name | ![]() | ![]() | |
| Available Temperature Settings (with remote) | 115, 120, 125, 130, 135, 140°F | ![]() | ![]() |
| Default Temperature Setting (without remote) | 120°F | ![]() | ![]() |
| Default Temperature Program Setting Options (without remote) | 120, 125, 130, 140°F | ![]() | ![]() |
| Production Date Range | 12/2017 - Present | ![]() | ![]() |
| Min Gas Input (Btu) | 18000 | ![]() | ![]() |
| Max Gas Input (Btu) | 180000 | ![]() | ![]() |
| Height (in) | 23.6 | ![]() | ![]() |
| Width (in) | 13.8 | ![]() | ![]() |
| Depth (in) | 9.4 | ![]() | ![]() |
| Weight (lbs) | 49 | ![]() | ![]() |
| Thermal Efficiency | N/A | ![]() | ![]() |
| Energy Factor | UEF 0.82 | ![]() | ![]() |
| Afue | N/A | ![]() | ![]() |
| Quick-Connect Compatible? | Yes | ![]() | ![]() |
| Cold Water Connection Size (in) | 3/4 | ![]() | ![]() |
| Hot Water Connection Size (in) | 3/4 | ![]() | ![]() |
| Gas Connection Size (in) | 3/4 | ![]() | ![]() |
| Power Supply | 120 VAC (60 Hz) | ![]() | ![]() |
| Current Draw (A) | 1.34 amps | ![]() | ![]() |
| Exhaust Vent Diameter Requirements | N/A | ![]() | ![]() |
| Exhaust Vent Material Requirements | N/A | ![]() | ![]() |
| Max Vent Length with 1 elbow | N/A | ![]() | ![]() |
| Vent Termination Clearances to Any Building Opening (ft) | Below = 4’, Side = 4’, or Above = 1’ | ![]() | ![]() |
| Gas Supply Pressure Range | 8 - 14" WC | ![]() | ![]() |
| Min Gas Line Size | 1/2" up to 20 feet, 3/4" up to 125 feet. | ![]() | ![]() |
| Water Pressure Rating (psi) | 15-150 | ![]() | ![]() |
| Case Clearances (in) | Top = 12", Front = 4", Sides = 2", Back = 0" | ![]() | ![]() |
| Combustion Air Requirements - using Indoor Air | N/A | ![]() | ![]() |
| Combustion Air Requirements - using Outdoor Air | N/A | ![]() | ![]() |
| Head Loss at 2 gpm | 7 ft of head | ![]() | ![]() |
| Cold Connection Height | 1.9" | ![]() | ![]() |
| Power Consumption w/out Freeze Prevention | 69 Watts | ![]() | ![]() |
| Power Consumption w/Freeze Prevention | 161 Watts | ![]() | ![]() |
| Flow Meter Alarm | Yes | ![]() | ![]() |
| Service Reminder | Yes | ![]() | ![]() |
| Condensate Handling Method? | N/A | ![]() | ![]() |
| Noise Rating (dB) | Less than 60 dB | ![]() | ![]() |
| Tested to UL Computer Controlled Safety Standards | Yes | ![]() | ![]() |
| Flame Sensor | Yes | ![]() | ![]() |
| High Limit Switch | Yes | ![]() | ![]() |
| Lightning Protection | Yes | ![]() | ![]() |
| Overheat Cutoff Fuse | Yes | ![]() | ![]() |
| Temperature Lockout | Yes | ![]() | ![]() |
| Ignition Type | Direct Electronic | ![]() | ![]() |
| Case Material | Durable Steel Casing with Polyester Coating | ![]() | ![]() |
| Color/Finish | Beige | ![]() | ![]() |
| Flue Collar Material | N/A | ![]() | ![]() |
| Primary Heat Exchanger Material | Copper | ![]() | ![]() |
| Secondary Heat Exchanger Material | N/A | ![]() | ![]() |
| Mounting Type | Wall Hung | ![]() | ![]() |
| Package Contents | Anchoring Screws, Owner’s Guide, Warranty, Installation Manual | ![]() | ![]() |
| Water Holding Capacity | 0.2 gallons | ![]() | ![]() |
| Keypad/Thermostat Display | Yes | ![]() | ![]() |
| Compatible Remote Controller Part # | RC-7651M (USA) | ![]() | ![]() |
| Isolator Valve Part # | IK-WV-200-1-xx | ![]() | ![]() |
| Freeze Protection | Built in | ![]() | ![]() |
| Freeze Protection Kit Accessory | N/A | ![]() | ![]() |
| Outdoor Vent Cap Part # | N/A | ![]() | ![]() |
| Pipe Cover Part # | PC-2S | ![]() | ![]() |
| Recess Box Part # | RB-700-1 | ![]() | ![]() |
| High Elevation Adjustment | Yes | ![]() | ![]() |
| Quick-Connect Cord Part # | QC-2 | ![]() | ![]() |
| System Controller Compatible? | No | ![]() | ![]() |
| System Controller Part # | N/A | ![]() | ![]() |
| Remote Controller Cord | Included | ![]() | ![]() |
| Compatible Remote Controller Cord Part # | N/A | ![]() | ![]() |
| Power Cord | Not included | ![]() | ![]() |
![]() | ![]() |
| Heat Exchanger Warranty (w/out Recirculation) | 12 Years | ![]() | ![]() |
| Heat Exchanger Warranty (w/Recirculation) | 12 Years w/Aquastat | ![]() | ![]() |