FAQ - Is there an issue with installing Noritz tankless water heaters on "off the grid" or solar power sources?
Article Number: 191 | Rating: Unrated | Last Updated: Fri, Dec 12, 2014 5:12 PM
A common issue with "off the grid" installations is the voltage signal that feeds the tankless water heater. Noritz water heaters require a pure sine wave voltage signal to operate properly. In situations where the unit will be installed on "off the grid" or solar power sources, the voltage signal should be verified. If a pure sine wave signal is not provided, an inverter will be required. Please contact a specialist within your area for further information about an inverter.
If a pure sine wave voltage signal is not supplied to the unit, a 71 code will appear and unit will not fire. This issue is can also appear when a battery back-up (UPS, uninterrupted power supply) does not provide a pure sine wave voltage signal.
Local Noritz installer can be located at: http://www.noritz.com/
Attachments
There are no attachments for this article.
Comments 

Please add a comment if you would like to provide us with feedback about this article. We will carefully analyze your feedback and use it to improve our Articles, but we will not reply to you. If you have an issue that requires a reply, please click here to contact us. If you have an urgent matter that needs immediate assistance, please call us at 866-766-7489. Otherwise, please feel free to search our website for what you need. Thank you for choosing Noritz!
Related Articles

There are no articles in this section.
Articles in same category

FAQ - What is the warranty on Noritz heaters?
Viewed 31000 times since Fri, Sep 30, 2011
FAQ - My unit is rumbling when it’s trying to fire.
Viewed 7471 times since Mon, Oct 3, 2011
FAQ - Is a horizontal section required for all vent runs that terminate vertically?
Viewed 6012 times since Fri, Sep 30, 2011

Add Comment