Product Information

allow Search by Model

Previous Name : EZ111
Residential or Commercial Residential
Installation Location Indoor & Outdoor
Exhaust Type 2-pipe Direct Vent (SV convertible), Flex and Outdoor with accessories
Max Flow Rate 11.1 GPM
Flow Rate @ 50°F Rise 8.9
Flow Rate @ 80°F Rise 4.9
Temperature Range 100-140°F
Production Status Active
Condensing Yes
Minimum Activation Flow Rate 0.5 GPM
Water Quality Treatment May Be Necessary
Freeze Protection Yes
Freeze Protection Rating - Indoor Temp -30°F
Freeze Protection Rating - Outdoor Temp -30°F
Recirculation Compatible? Yes
New Generation Model Number N/A
Previous Name EZ111
Available Temperature Settings (with remote) 100-140°F (In 5°F intervals) (9 Options)
Default Temperature Setting (without remote) 120°F
Default Temperature Program Setting Options (without remote) 120, 125, 130, 140°F
Production Date Range 6/2020- Present
Min Gas Input (Btu) 18,000
Max Gas Input (Btu) 199,900
Height (in) 27
Width (in) 18.5
Depth (in) 12.8
Weight (lbs) 81
Thermal Efficiency
Energy Factor UEF 0.95
Afue N/A
Quick-Connect Compatible? Yes
Cold Water Connection Size (in) 3/4
Hot Water Connection Size (in) 3/4
Gas Connection Size (in) 3/4
Power Supply 120 VAC
Current Draw (A) 2.55
Exhaust Vent Diameter Requirements 2" or 3"
Exhaust Vent Material Requirements PVC/CPVC and flex
Max Vent Length with 1 elbow 65’ with 2" or 150’ with 3"
Vent Termination Clearances to Any Building Opening (ft) Below = 1’, Side = 1’, or Above = 1’
Gas Supply Pressure Range 8-14" WC
Min Gas Line Size 3/4" up to 59’
Water Pressure Rating (psi) 15-150
Case Clearances (in) Top = 12", Front = 4", Sides = 3", Back = 0"
Combustion Air Requirements - using Indoor Air 200 in² (Only if SV conversion)
Combustion Air Requirements - using Outdoor Air 50 in² for Direct or Vertical Ducts & 100 in² for Horizontal Ducts (Only if SV conversion)
Head Loss at 2 gpm 8.9 ft
Cold Connection Height 2.3"
Power Consumption w/out Freeze Prevention 80 Watts
Power Consumption w/Freeze Prevention 114 Watts
Flow Meter Alarm Yes
Service Reminder Yes
Condensate Handling Method? NC-1
Noise Rating (dB) 52 dB
Tested to UL Computer Controlled Safety Standards Yes
Flame Sensor Yes
High Limit Switch Yes
Lightning Protection Yes
Overheat Cutoff Fuse Yes
Temperature Lockout Yes
Ignition Type Direct Electronic
Case Material Durable Steel
Color/Finish Metallic Silver
Flue Collar Material PP
Primary Heat Exchanger Material Stainless Steel
Secondary Heat Exchanger Material Stainless Steel
Mounting Type Wall Hung
Package Contents Anchoring Screws, Remote Controller, Remote Controller Cord, Owner’s Guide, Warranty, Installation Manual, Wall Mounting Bracket
Water Holding Capacity 0.79 gal
Keypad/Thermostat Display Included
Compatible Remote Controller Part # RC-7651M, Optional:RC-9018M
Isolator Valve Part # IK-WV-200-1-SW-LF and IK-WV-200-1-TH-LF
Freeze Protection Yes
Freeze Protection Kit Accessory
Outdoor Vent Cap Part # VC-6
Pipe Cover Part # PC-10S
Recess Box Part # N/A
High Elevation Adjustment Yes
Quick-Connect Cord Part # QC-2
System Controller Compatible? No
System Controller Part # N/A
Remote Controller Cord Included
Compatible Remote Controller Cord Part # RC-CORD10 and RC-CORD26
Power Cord Included attached
ENERGY STAR® Qualified Yes
CSA Yes
Mobile Home Yes
NSF Yes
SCAQMD (20 ppm) Yes
SCAQMD (55 ppm) No
UPC Yes
Energy Guide - Est. Yearly Energy Use 191 Gallons
Energy Guide - Est. Yearly Operating Cost $460
UPC Low Lead Yes
ASME (HLW) No
ASME (H) No
ASME (NB) No
Heat Exchanger Warranty (w/out Recirculation) 25 years
Heat Exchanger Warranty (w/Recirculation) 15 Years with Aquastat
Parts Warranty 5 years
Labor Warranty 1 year
Go to Warranty Calculator
Residential or Commercial Residential
Installation Location Indoor & Outdoor
Exhaust Type 2-pipe Direct Vent (SV convertible), Flex and Outdoor with accessories
Max Flow Rate 11.1 GPM
Flow Rate @ 50°F Rise 8.9
Flow Rate @ 80°F Rise 4.9
Temperature Range 100-140°F
Production Status Active
Condensing Yes
Minimum Activation Flow Rate 0.5 GPM
Water Quality Treatment May Be Necessary
Freeze Protection Yes
Freeze Protection Rating - Indoor Temp -30°F
Freeze Protection Rating - Outdoor Temp -30°F
Recirculation Compatible? Yes
New Generation Model Number N/A
Previous Name EZ111
Available Temperature Settings (with remote) 100-140°F (In 5°F intervals) (9 Options)
Default Temperature Setting (without remote) 120°F
Default Temperature Program Setting Options (without remote) 120, 125, 130, 140°F
Production Date Range 6/2020- Present
Min Gas Input (Btu) 18,000
Max Gas Input (Btu) 199,900
Height (in) 27
Width (in) 18.5
Depth (in) 12.8
Weight (lbs) 81
Thermal Efficiency
Energy Factor UEF 0.95
Afue N/A
Quick-Connect Compatible? Yes
Cold Water Connection Size (in) 3/4
Hot Water Connection Size (in) 3/4
Gas Connection Size (in) 3/4
Power Supply 120 VAC
Current Draw (A) 2.55
Exhaust Vent Diameter Requirements 2" or 3"
Exhaust Vent Material Requirements PVC/CPVC and flex
Max Vent Length with 1 elbow 65’ with 2" or 150’ with 3"
Vent Termination Clearances to Any Building Opening (ft) Below = 1’, Side = 1’, or Above = 1’
Gas Supply Pressure Range 8-14" WC
Min Gas Line Size 3/4" up to 59’
Water Pressure Rating (psi) 15-150
Case Clearances (in) Top = 12", Front = 4", Sides = 3", Back = 0"
Combustion Air Requirements - using Indoor Air 200 in² (Only if SV conversion)
Combustion Air Requirements - using Outdoor Air 50 in² for Direct or Vertical Ducts & 100 in² for Horizontal Ducts (Only if SV conversion)
Head Loss at 2 gpm 8.9 ft
Cold Connection Height 2.3"
Power Consumption w/out Freeze Prevention 80 Watts
Power Consumption w/Freeze Prevention 114 Watts
Flow Meter Alarm Yes
Service Reminder Yes
Condensate Handling Method? NC-1
Noise Rating (dB) 52 dB
Tested to UL Computer Controlled Safety Standards Yes
Flame Sensor Yes
High Limit Switch Yes
Lightning Protection Yes
Overheat Cutoff Fuse Yes
Temperature Lockout Yes
Ignition Type Direct Electronic
Case Material Durable Steel
Color/Finish Metallic Silver
Flue Collar Material PP
Primary Heat Exchanger Material Stainless Steel
Secondary Heat Exchanger Material Stainless Steel
Mounting Type Wall Hung
Package Contents Anchoring Screws, Remote Controller, Remote Controller Cord, Owner’s Guide, Warranty, Installation Manual, Wall Mounting Bracket
Water Holding Capacity 0.79 gal
Keypad/Thermostat Display Included
Compatible Remote Controller Part # RC-7651M, Optional:RC-9018M
Isolator Valve Part # IK-WV-200-1-SW-LF and IK-WV-200-1-TH-LF
Freeze Protection Yes
Freeze Protection Kit Accessory
Outdoor Vent Cap Part # VC-6
Pipe Cover Part # PC-10S
Recess Box Part # N/A
High Elevation Adjustment Yes
Quick-Connect Cord Part # QC-2
System Controller Compatible? No
System Controller Part # N/A
Remote Controller Cord Included
Compatible Remote Controller Cord Part # RC-CORD10 and RC-CORD26
Power Cord Included attached
ENERGY STAR® Qualified Yes
CSA Yes
Mobile Home Yes
NSF Yes
SCAQMD (20 ppm) Yes
SCAQMD (55 ppm) No
UPC Yes
Energy Guide - Est. Yearly Energy Use 191 Gallons
Energy Guide - Est. Yearly Operating Cost $460
UPC Low Lead Yes
ASME (HLW) No
ASME (H) No
ASME (NB) No
Heat Exchanger Warranty (w/out Recirculation) 25 years
Heat Exchanger Warranty (w/Recirculation) 15 Years with Aquastat
Parts Warranty 5 years
Labor Warranty 1 year