Previous Name : N-0751M-OD-LP
Residential or Commercial Residential
Installation Location Outdoor Only
Exhaust Type Frontal Exhaust
Max Flow Rate 9.8 GPM
Flow Rate @ 50°F Rise 6.7 GPM
Flow Rate @ 80°F Rise 4.2 GPM
Temperature Range 100°F - 180°F
Production Status Discontinued
Condensing No
Minimum Activation Flow Rate 0.5
Water Quality Treatment May Be Necessary
Freeze Protection Yes
Freeze Protection Rating - Indoor Temp N/A
Freeze Protection Rating - Outdoor Temp -4°F
Recirculation Compatible? Yes
New Generation Model Number N/A
Previous Name N-0751M-OD-LP
Available Temperature Settings (with remote) 100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 160, 170, 180°F
Default Temperature Setting (without remote) 120°F
Default Temperature Program Setting Options (without remote) 120, 130, 140, 180°F
Production Date Range 01/2007 - Present
Min Gas Input (Btu) 12000
Max Gas Input (Btu) 199900
Height (in) 23.6
Width (in) 13.8
Depth (in) 9.4
Weight (lbs) 47
Thermal Efficiency
Energy Factor UEF 0.82
Afue N/A
Quick-Connect Compatible? Yes
Cold Water Connection Size (in) 3/4
Hot Water Connection Size (in) 3/4
Gas Connection Size (in) 3/4
Power Supply 120 VAC (60 Hz)
Current Draw (A) 1.208
Exhaust Vent Diameter Requirements N/A
Exhaust Vent Material Requirements N/A
Max Vent Length with 1 elbow N/A
Vent Termination Clearances to Any Building Opening (ft) Below = 1’, Side = 1’, or Above = 1’
Gas Supply Pressure Range 8 - 14" WC
Min Gas Line Size 3/4" up to 60’
Water Pressure Rating (psi) 15-150
Case Clearances (in) Top = 36", Front = 24", Sides = 6", Back = 0"
Combustion Air Requirements - using Indoor Air N/A
Combustion Air Requirements - using Outdoor Air N/A
Head Loss at 2 gpm 4.62 ft of head
Cold Connection Height 2.2"
Power Consumption w/out Freeze Prevention 77 Watts
Power Consumption w/Freeze Prevention 145 Watts
Flow Meter Alarm Yes
Service Reminder No
Condensate Handling Method? N/A
Noise Rating (dB) Less than 60 dB
Tested to UL Computer Controlled Safety Standards Yes
Flame Sensor Yes
High Limit Switch Yes
Lightning Protection Yes
Overheat Cutoff Fuse Yes
Temperature Lockout Yes
Ignition Type Direct Electronic
Case Material Durable Steel Casing with Polyester Coating
Color/Finish Beige
Flue Collar Material Stainless Steel
Primary Heat Exchanger Material Copper
Secondary Heat Exchanger Material N/A
Mounting Type Wall Hung
Package Contents Cross Recess Head Screws, Remote Controller, Remote Controller Cord, Owner’s Guide, Warranty, Installation Manual
Water Holding Capacity 0.2 gallons
Keypad/Thermostat Display Included
Compatible Remote Controller Part # RC-7649M
Isolator Valve Part # IK-WV-200-1-xx
Freeze Protection Yes
Freeze Protection Kit Accessory N/A
Outdoor Vent Cap Part # N/A
Pipe Cover Part # PC-2S
Recess Box Part # RB-700
High Elevation Adjustment Yes
Quick-Connect Cord Part # QC-1
System Controller Compatible? No
System Controller Part # N/A
Remote Controller Cord Included
Compatible Remote Controller Cord Part # RC-CORD10
Power Cord N/A
ENERGY STAR® Qualified Yes
CSA Yes
Mobile Home Yes
NSF Yes
SCAQMD (20 ppm) No
SCAQMD (55 ppm) Yes
UPC No
Energy Guide - Est. Yearly Energy Use 200 gallons
Energy Guide - Est. Yearly Operating Cost $374
UPC Low Lead Yes
ASME (HLW) No
ASME (H) No
ASME (NB) No
Heat Exchanger Warranty (w/out Recirculation) 12 Years
Heat Exchanger Warranty (w/Recirculation) 12 Yrs. w/ Aquastat
Parts Warranty 5 Years
Labor Warranty 1 Year
Go to Warranty Calculator
Residential or Commercial Residential
Installation Location Outdoor Only
Exhaust Type Frontal Exhaust
Max Flow Rate 9.8 GPM
Flow Rate @ 50°F Rise 6.7 GPM
Flow Rate @ 80°F Rise 4.2 GPM
Temperature Range 100°F - 180°F
Production Status Discontinued
Condensing No
Minimum Activation Flow Rate 0.5
Water Quality Treatment May Be Necessary
Freeze Protection Yes
Freeze Protection Rating - Indoor Temp N/A
Freeze Protection Rating - Outdoor Temp -4°F
Recirculation Compatible? Yes
New Generation Model Number N/A
Previous Name N-0751M-OD-LP
Available Temperature Settings (with remote) 100, 105, 110, 115, 120, 125, 130, 135, 140, 145, 150, 160, 170, 180°F
Default Temperature Setting (without remote) 120°F
Default Temperature Program Setting Options (without remote) 120, 130, 140, 180°F
Production Date Range 01/2007 - Present
Min Gas Input (Btu) 12000
Max Gas Input (Btu) 199900
Height (in) 23.6
Width (in) 13.8
Depth (in) 9.4
Weight (lbs) 47
Thermal Efficiency
Energy Factor UEF 0.82
Afue N/A
Quick-Connect Compatible? Yes
Cold Water Connection Size (in) 3/4
Hot Water Connection Size (in) 3/4
Gas Connection Size (in) 3/4
Power Supply 120 VAC (60 Hz)
Current Draw (A) 1.208
Exhaust Vent Diameter Requirements N/A
Exhaust Vent Material Requirements N/A
Max Vent Length with 1 elbow N/A
Vent Termination Clearances to Any Building Opening (ft) Below = 1’, Side = 1’, or Above = 1’
Gas Supply Pressure Range 8 - 14" WC
Min Gas Line Size 3/4" up to 60’
Water Pressure Rating (psi) 15-150
Case Clearances (in) Top = 36", Front = 24", Sides = 6", Back = 0"
Combustion Air Requirements - using Indoor Air N/A
Combustion Air Requirements - using Outdoor Air N/A
Head Loss at 2 gpm 4.62 ft of head
Cold Connection Height 2.2"
Power Consumption w/out Freeze Prevention 77 Watts
Power Consumption w/Freeze Prevention 145 Watts
Flow Meter Alarm Yes
Service Reminder No
Condensate Handling Method? N/A
Noise Rating (dB) Less than 60 dB
Tested to UL Computer Controlled Safety Standards Yes
Flame Sensor Yes
High Limit Switch Yes
Lightning Protection Yes
Overheat Cutoff Fuse Yes
Temperature Lockout Yes
Ignition Type Direct Electronic
Case Material Durable Steel Casing with Polyester Coating
Color/Finish Beige
Flue Collar Material Stainless Steel
Primary Heat Exchanger Material Copper
Secondary Heat Exchanger Material N/A
Mounting Type Wall Hung
Package Contents Cross Recess Head Screws, Remote Controller, Remote Controller Cord, Owner’s Guide, Warranty, Installation Manual
Water Holding Capacity 0.2 gallons
Keypad/Thermostat Display Included
Compatible Remote Controller Part # RC-7649M
Isolator Valve Part # IK-WV-200-1-xx
Freeze Protection Yes
Freeze Protection Kit Accessory N/A
Outdoor Vent Cap Part # N/A
Pipe Cover Part # PC-2S
Recess Box Part # RB-700
High Elevation Adjustment Yes
Quick-Connect Cord Part # QC-1
System Controller Compatible? No
System Controller Part # N/A
Remote Controller Cord Included
Compatible Remote Controller Cord Part # RC-CORD10
Power Cord N/A
ENERGY STAR® Qualified Yes
CSA Yes
Mobile Home Yes
NSF Yes
SCAQMD (20 ppm) No
SCAQMD (55 ppm) Yes
UPC No
Energy Guide - Est. Yearly Energy Use 200 gallons
Energy Guide - Est. Yearly Operating Cost $374
UPC Low Lead Yes
ASME (HLW) No
ASME (H) No
ASME (NB) No
Heat Exchanger Warranty (w/out Recirculation) 12 Years
Heat Exchanger Warranty (w/Recirculation) 12 Yrs. w/ Aquastat
Parts Warranty 5 Years
Labor Warranty 1 Year
Go to Warranty Calculator
ENERGYSTAR CSA NSF SCAQMD55 LeadFree

Subscribe to Knowledgebase

Get notified when Knowledgebase articles are added or updated.
Get notified when Knowledgebase articles are added or updated.
Subscribe
VIEW FULL SITE
Copyright © 2020, NORITZ AMERICA CORP.All Rights Reserved