Residential or Commercial | Residential | ||
Installation Location | Indoor | ||
Exhaust Type | 2-pipe Direct Vent (SV convertible) | ||
Max Flow Rate | 10.1 GPM | ||
Flow Rate @ 50°F Rise | 7.0 | ||
Flow Rate @ 80°F Rise | 3.8 | ||
Temperature Range | 100-140°F | ||
Production Status | Active | ||
Condensing | Yes | ||
Minimum Activation Flow Rate | 0.5 GPM | ||
Water Quality | Water Treatment may be needed |
Freeze Protection | Yes | ||
Freeze Protection Rating - Indoor Temp | -30°F | ||
Freeze Protection Rating - Outdoor Temp | N/A | ||
Recirculation Compatible? | Yes | ||
New Generation Model Number | NRCP98 | ||
Previous Name | N/A | ||
Available Temperature Settings (with remote) | 100, 105, 110, 115, 120, 125, 130, 135, 140°F | ||
Default Temperature Setting (without remote) | N/A | ||
Default Temperature Program Setting Options (without remote) | N/A | ||
Production Date Range | 10/14 - present |
Min Gas Input (Btu) | 18000 | ||
Max Gas Input (Btu) | 180000 | ||
Height (in) | 28.7 | ||
Width (in) | 17.3 | ||
Depth (in) | 14.8 | ||
Weight (lbs) | 85 | ||
Thermal Efficiency | N/A | ||
Energy Factor | UEF=0.94 | ||
Afue | N/A | ||
Quick-Connect Compatible? | No | ||
Cold Water Connection Size (in) | 3/4 | ||
Hot Water Connection Size (in) | 3/4 | ||
Gas Connection Size (in) | 3/4 | ||
Power Supply | 120 VAC | ||
Current Draw (A) | 1.43 | ||
Exhaust Vent Diameter Requirements | 2" or 3" | ||
Exhaust Vent Material Requirements | PVC or CPVC | ||
Max Vent Length with 1 elbow | 95’ with 3" or 42’ with 2" | ||
Vent Termination Clearances to Any Building Opening (ft) | Below = 1’, Side = 1’, or Above = 1’ | ||
Gas Supply Pressure Range | 8-14" w.c. | ||
Min Gas Line Size | 3/4" up to 30’ | ||
Water Pressure Rating (psi) | 15-150 | ||
Case Clearances (in) | Top = 12", Front = 4", Sides = 2", Back = 5/8", Below = 12" | ||
Combustion Air Requirements - using Indoor Air | 199 in² (Only if SV conversion) |
Combustion Air Requirements - using Outdoor Air | 100 in²(Only if SV conversion) | ||
Head Loss at 2 gpm | |||
Cold Connection Height | 3.2" | ||
Power Consumption w/out Freeze Prevention | 172 W | ||
Power Consumption w/Freeze Prevention | 172 W | ||
Flow Meter Alarm | N/A | ||
Service Reminder | N/A | ||
Condensate Handling Method? | NC-1 | ||
Noise Rating (dB) | Less than 60 dB | ||
Tested to UL Computer Controlled Safety Standards | Yes | ||
Flame Sensor | Yes | ||
High Limit Switch | Yes | ||
Lightning Protection | Yes | ||
Overheat Cutoff Fuse | No | ||
Temperature Lockout | Yes | ||
Ignition Type | Direct Electric | ||
Case Material | Cold Rolled Carbon Steel | ||
Color/Finish | Grey | ||
Flue Collar Material | |||
Primary Heat Exchanger Material | Stainless Steel | ||
Secondary Heat Exchanger Material | Stainless Steel | ||
Mounting Type | Wall Hung | ||
Package Contents | Anchoring Screws, Wall Mounting Bracket, Emergency Kit, Owner’s Guide, Warranty, Installation Manual | ||
Water Holding Capacity | under 2 gallons |
Keypad/Thermostat Display | Included | ||
Compatible Remote Controller Part # | P-950C (Part # NPJ089) | ||
Isolator Valve Part # | IK-WK-200-1-XX | ||
Freeze Protection | Yes | ||
Freeze Protection Kit Accessory | N/A | ||
Outdoor Vent Cap Part # | N/A | ||
Pipe Cover Part # | N/A | ||
Recess Box Part # | N/A |
High Elevation Adjustment | Yes | ||
Quick-Connect Cord Part # | QC-NRCP-1 | ||
System Controller Compatible? | No | ||
System Controller Part # | N/A | ||
Remote Controller Cord | N/A | ||
Compatible Remote Controller Cord Part # | |||
Power Cord | Included attached | ||
Heat Exchanger Warranty (w/out Recirculation) | 12 years | ||
Heat Exchanger Warranty (w/Recirculation) | 12 years |
Parts Warranty | 5 years | ||
Labor Warranty | 1 year |
Residential or Commercial | Residential | ||
Installation Location | Indoor | ||
Exhaust Type | 2-pipe Direct Vent (SV convertible) | ||
Max Flow Rate | 10.1 GPM | ||
Flow Rate @ 50°F Rise | 7.0 | ||
Flow Rate @ 80°F Rise | 3.8 | ||
Temperature Range | 100-140°F | ||
Production Status | Active | ||
Condensing | Yes | ||
Minimum Activation Flow Rate | 0.5 GPM | ||
Water Quality | Water Treatment may be needed |
Freeze Protection | Yes | ||
Freeze Protection Rating - Indoor Temp | -30°F | ||
Freeze Protection Rating - Outdoor Temp | N/A | ||
Recirculation Compatible? | Yes | ||
New Generation Model Number | NRCP98 | ||
Previous Name | N/A | ||
Available Temperature Settings (with remote) | 100, 105, 110, 115, 120, 125, 130, 135, 140°F | ||
Default Temperature Setting (without remote) | N/A | ||
Default Temperature Program Setting Options (without remote) | N/A | ||
Production Date Range | 10/14 - present |
Min Gas Input (Btu) | 18000 | ||
Max Gas Input (Btu) | 180000 | ||
Height (in) | 28.7 | ||
Width (in) | 17.3 | ||
Depth (in) | 14.8 | ||
Weight (lbs) | 85 | ||
Thermal Efficiency | N/A | ||
Energy Factor | UEF=0.94 | ||
Afue | N/A | ||
Quick-Connect Compatible? | No | ||
Cold Water Connection Size (in) | 3/4 | ||
Hot Water Connection Size (in) | 3/4 | ||
Gas Connection Size (in) | 3/4 | ||
Power Supply | 120 VAC | ||
Current Draw (A) | 1.43 | ||
Exhaust Vent Diameter Requirements | 2" or 3" | ||
Exhaust Vent Material Requirements | PVC or CPVC | ||
Max Vent Length with 1 elbow | 95’ with 3" or 42’ with 2" | ||
Vent Termination Clearances to Any Building Opening (ft) | Below = 1’, Side = 1’, or Above = 1’ | ||
Gas Supply Pressure Range | 8-14" w.c. | ||
Min Gas Line Size | 3/4" up to 30’ | ||
Water Pressure Rating (psi) | 15-150 | ||
Case Clearances (in) | Top = 12", Front = 4", Sides = 2", Back = 5/8", Below = 12" | ||
Combustion Air Requirements - using Indoor Air | 199 in² (Only if SV conversion) |
Combustion Air Requirements - using Outdoor Air | 100 in²(Only if SV conversion) | ||
Head Loss at 2 gpm | |||
Cold Connection Height | 3.2" | ||
Power Consumption w/out Freeze Prevention | 172 W | ||
Power Consumption w/Freeze Prevention | 172 W | ||
Flow Meter Alarm | N/A | ||
Service Reminder | N/A | ||
Condensate Handling Method? | NC-1 | ||
Noise Rating (dB) | Less than 60 dB | ||
Tested to UL Computer Controlled Safety Standards | Yes | ||
Flame Sensor | Yes | ||
High Limit Switch | Yes | ||
Lightning Protection | Yes | ||
Overheat Cutoff Fuse | No | ||
Temperature Lockout | Yes | ||
Ignition Type | Direct Electric | ||
Case Material | Cold Rolled Carbon Steel | ||
Color/Finish | Grey | ||
Flue Collar Material | |||
Primary Heat Exchanger Material | Stainless Steel | ||
Secondary Heat Exchanger Material | Stainless Steel | ||
Mounting Type | Wall Hung | ||
Package Contents | Anchoring Screws, Wall Mounting Bracket, Emergency Kit, Owner’s Guide, Warranty, Installation Manual | ||
Water Holding Capacity | under 2 gallons |
Keypad/Thermostat Display | Included | ||
Compatible Remote Controller Part # | P-950C (Part # NPJ089) | ||
Isolator Valve Part # | IK-WK-200-1-XX | ||
Freeze Protection | Yes | ||
Freeze Protection Kit Accessory | N/A | ||
Outdoor Vent Cap Part # | N/A | ||
Pipe Cover Part # | N/A | ||
Recess Box Part # | N/A |
High Elevation Adjustment | Yes | ||
Quick-Connect Cord Part # | QC-NRCP-1 | ||
System Controller Compatible? | No | ||
System Controller Part # | N/A | ||
Remote Controller Cord | N/A | ||
Compatible Remote Controller Cord Part # | |||
Power Cord | Included attached | ||
Heat Exchanger Warranty (w/out Recirculation) | 12 years | ||
Heat Exchanger Warranty (w/Recirculation) | 12 years |
Parts Warranty | 5 years | ||
Labor Warranty | 1 year |