FAQ - How To Install Remotes

 
Please also see installation manual located at:  http://support.noritz.com/technical-literature.php
 
 
 
 
 
How to Install Remotes (All Units)

 

 
 
 
 

 

 

 Figure 1. Remote controller and remote control Cord

 
Procedure is also detailed in the installation manual located at :
 

Considerations on the installation location:

·        The remote should be installed in an easily accessible location.

·        Avoid installing in a place where the water or steam can come into contact with the controller.

·        Avoid locations where special chemical agents (e.g., benzene, fatty and oily detergents) are used.

 id oavoid outdoor installation, or installation in an indoor location where it will be exposed to direct sunlight.

 

 

Figure 1a. Remote control cord

Connection of the Remote Controller Cord:

·        White Connector -> To Remote Controller (Figure 1.)

·        Y-Shaped terminals->To Water heater (Figure 1.)

·        A 26’ cord can be purchased separately(Part# RC-CORD26)

*Confirm the connection with the labels at both ends of the remote controller cord.

·        The remote controller cord can be extended up to 300 ft. by splicing the cord and using 18 gauge wire to extend the cord to the appropriate length.

Types of Remote Terminal Blocks:

                        

                                Figure 2. (Left to Right) Internal, Circuit board mounted, and External connection terminal blocks

There are several types of remote terminal block connections found in our water heaters. Many of our older models have internally mounted terminal blocks located near the GFCI on the left or right hand side of the water heater. Smaller water heaters such as the N-0531S and N-0631S feature a circuit board mounted remote terminal block which is conveniently labeled. Newer models of our tankless water heaters feature an externally mounted terminal block connection found on the left hand side under the water heater.

 

·        Internal & Circuit board mounted terminal block type:

1.  Leave enough slack so that the remote controller cord will not be damaged if the unit is removed from the wall.

2. Remove the front cover of the heater (4 screws).

3.  Pass the remote controller cord through the wiring throughway and into the unit.                                                                                                                                         

 

4. Connect the Y terminals at the end of the remote controller cord to the terminal block.

  

 

5. Secure the remote controller cord with a clamp.          

6. Replace the front cover.

 

*Applicable to: N-063S-(OD), N-069M-(OD/DV), N-084M-(DV)[ right side], N-132M[ right side]. N-0531S-(OD), N-0631S-(OD), N-0751M-(OD/DV), N-0931M-(OD/DV),up to revision 3-08, N-1321M-ASME  [right side].

 

 

·        External connection terminal block type (Newer Models):


1. Check to make sure that the remote controller cord has plenty of slack in order to reach the external connection terminal block.

2. Disconnect electrical power to the water heater.

3. Remove the single screw securing the terminal block cover and then remove the cover.

4. Pass the remote controller cord through the wiring throughway and connect the Y terminals at the end

of the remote controller cord to the terminal block.  

5. Replace the terminal block cover and install the screw previously removed in step 3.

6. Reconnect electrical power to the water heater.    

 

*Applicable to: N-0531S-(OD), N-0631S-(OD), N-0751M-(OD/DV), N-0841MC-(DV) N-0931M-(OD/DV) starting revision 4-08.

 

Attaching the remote to the Wall:




 

 

 

Applicable Models
  • Models: ALL MODELS
Attachments
There are no attachments for this article.
Comments Comments
Please add a comment if you would like to provide us with feedback about this article. We will carefully analyze your feedback and use it to improve our Articles, but we will not reply to you. If you have an issue that requires a reply, please click here to contact us. If you have an urgent matter that needs immediate assistance, please call us at 866-766-7489. Otherwise, please feel free to search our website for what you need. Thank you for choosing Noritz!

Related Articles

There are no articles in this section.

Articles in same category

FAQ - What size pump should I use on my recirculation system?
Viewed 9911 times since Fri, Sep 30, 2011
FAQ - What does the flow meter alarm set button do? What does 990 mean?
Viewed 21032 times since Fri, Sep 30, 2011
FAQ - Is a battery back-up supply recommended with your units?
Viewed 9899 times since Mon, Oct 3, 2011
Article Rating (1 Votes)
Rate this article

Subscribe to Knowledgebase

Get notified when Knowledgebase articles are added or updated.
Get notified when Knowledgebase articles are added or updated.
Subscribe
VIEW FULL SITE
Copyright © 2020, NORITZ AMERICA CORP.All Rights Reserved